NOARK® Motor-Circuit Protector 150A Frame M1, N IC Class 3P | M1MN150T3L
Product Details : NOARK® Motor-Circuit Protector 150A Frame M1, N IC Class 3P | M1MN150T3L
- Part No: M1MN150T3L
- Product Type: NOARK® Motor-Circuit Protector
- Brand: NOARK®
- Series: M1M
- Frame Size: Frame M1
- IC Class: N (High Interrupting Capacity)
- Interrupting Capacity: 65kA @ 480Vac
- Rated Current (Amps): 150A
- No. Of Poles: 3
- Connection Type: Lug Line/Load Side
- Cam Setting: A, B, C, D, E, F, G
- Full Load Current at Cam Setting A: 57.7 to 69.1 A
- Full Load Current at Cam Setting B: 69.2 to 80.6 A
- Full Load Current at Cam Setting C: 80.7 to 92.2 A
- Full Load Current at Cam Setting D: 92.3 to 103.7 A
- Full Load Current at Cam Setting E: 103.8 to 115.2 A
- Full Load Current at Cam Setting F: 115.3 to 126.7 A
- Full Load Current at Cam Setting G: 126.9 to 130.5 A
- (MCP) Trip Setting at Cam Setting A: 750
- (MCP) Trip Setting at Cam Setting B: 900
- (MCP) Trip Setting at Cam Setting C: 1050
- (MCP) Trip Setting at Cam Setting D: 1200
- (MCP) Trip Setting at Cam Setting E: 1350
- (MCP) Trip Setting at Cam Setting F: 1500
- (MCP) Trip Setting at Cam Setting G: 1650
For any information about products, please contact us.
*Photos for reference purposes only.
Original: $301.87
-65%$301.87
$105.65

Description
Product Details : NOARK® Motor-Circuit Protector 150A Frame M1, N IC Class 3P | M1MN150T3L
- Part No: M1MN150T3L
- Product Type: NOARK® Motor-Circuit Protector
- Brand: NOARK®
- Series: M1M
- Frame Size: Frame M1
- IC Class: N (High Interrupting Capacity)
- Interrupting Capacity: 65kA @ 480Vac
- Rated Current (Amps): 150A
- No. Of Poles: 3
- Connection Type: Lug Line/Load Side
- Cam Setting: A, B, C, D, E, F, G
- Full Load Current at Cam Setting A: 57.7 to 69.1 A
- Full Load Current at Cam Setting B: 69.2 to 80.6 A
- Full Load Current at Cam Setting C: 80.7 to 92.2 A
- Full Load Current at Cam Setting D: 92.3 to 103.7 A
- Full Load Current at Cam Setting E: 103.8 to 115.2 A
- Full Load Current at Cam Setting F: 115.3 to 126.7 A
- Full Load Current at Cam Setting G: 126.9 to 130.5 A
- (MCP) Trip Setting at Cam Setting A: 750
- (MCP) Trip Setting at Cam Setting B: 900
- (MCP) Trip Setting at Cam Setting C: 1050
- (MCP) Trip Setting at Cam Setting D: 1200
- (MCP) Trip Setting at Cam Setting E: 1350
- (MCP) Trip Setting at Cam Setting F: 1500
- (MCP) Trip Setting at Cam Setting G: 1650
For any information about products, please contact us.
*Photos for reference purposes only.